Honeywell Intermittent pilot kit Y8610U6006/U
SKU Y8610U6006/U
Brand Honeywell
Photos
Key specifications
| Burner system type | intermittent pilot |
|---|---|
| Flame sensing method | ionisation current measurement |
| Pilot burner system type | intermittent pilot |
| Gas types | natural gas, LPG |
| Compatible fuel types | natural gas, liquefied petroleum gas |
| Application | gas-fired burners |
| Pilot flame mode | intermittent |
| Controller model | S8610U3009 |
| Gas valve model | VR8304M3558 |
| Pilot burner model | 390427T |
| Flange model | 393690–14 |
| LP gas conversion kit model | 393691 |
| High voltage cable model | 394800–30 |
| Length | 760 mm |
| Electrode configuration | L-shaped 6mm electrode connection |
| Electrical connection | flat terminal 6.35x0.8mm to controller |
613.78 EUR
557.98EUR
in stock · 5
incl. 21% VAT · 461.14 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Honeywell Y8610U6006/U is an intermittent pilot kit for gas-fired burners. It includes a S8610U3009 controller, a VR8304M3558 gas valve, a 390427T pilot burner, a 393690-14 flange, a 393691 natural-gas-to-LPG conversion kit, and a 394800-30 high-voltage cable 760 mm long with a flat 6.35x0.8 mm terminal and an L-shaped 6 mm electrode connection. The system operates on an intermittent pilot flame, igniting at each heat demand and extinguishing on shutdown. Flame is proved by ionisation current measurement. It supports natural gas and LPG fuel types.
Further details
| Ignition System | spark ignition electrode and flame sensing electrode |
|---|---|
| Included components | controller, flange, ignition wire, wiring, pilot burner fitting, pilot burner, LP gas conversion kit |
| Operating principle | Gas valve opens only after the pilot flame has been proved |
Choosing and fitting
For replacement of an intermittent pilot kit, match the pilot burner tip design, electrode gap, gas type (natural gas or LPG), and connector dimensions to the original equipment. The kit must be approved for the specific burner control and gas valve models. During installation, verify the pilot burner orifice matches the gas supply pressure and route electrode wires away from hot surfaces and high-voltage cables.
All specifications
| Burner system type | intermittent pilot |
|---|---|
| Flame sensing method | ionisation current measurement |
| Pilot burner system type | intermittent pilot |
| Gas types | natural gas, LPG |
| Compatible fuel types | natural gas, liquefied petroleum gas |
| Application | gas-fired burners |
| Pilot flame mode | intermittent |
| Controller model | S8610U3009 |
| Gas valve model | VR8304M3558 |
| Pilot burner model | 390427T |
| Flange model | 393690–14 |
| LP gas conversion kit model | 393691 |
| High voltage cable model | 394800–30 |
| Length | 760 mm |
| Electrode configuration | L-shaped 6mm electrode connection |
| Electrical connection | flat terminal 6.35x0.8mm to controller |
Part numbers
| SKU | Y8610U6006/U |
|---|---|
| Additional article | 534.322.262 |
| Type designation | S8610U3009 |
| Type designation | VR8304M3558 |
| Type designation | 392431 |
| Type designation | 393690-14 |
| Type designation | 393691 |
| Type designation | 394800-30 |
| Type designation | 390427T |