Danfoss Oil pump BFP21 L3 071N7170
SKU 071N7170
Model BFP21 L3
Brand Danfoss
Photos
Key specifications
| Protection class (IP) | IP40 |
|---|---|
| Viscosity range (suction line) | 1.8-12.0 cst(mm2/s) |
| Filter area / cross-section | 11/200 cm2/microns |
| Setting range | 7000–20000 mbar |
| Max. pressure in suction/return line | 2 bar |
| Shaft rotation speed | 2400-3450 min |
| Max. starting torque | 0.1 nm |
| Ambient temperature | -20–70 °C |
| Storage temperature | -25–120 °C |
| Fuel temperature | 0–70 °C |
| Max. inlet pressure | 2000 mbar |
| Torque, Nm | 0.1 Nm |
| Application | small and medium-sized household burners |
| Fuel consumption | 42 l/h |
| Pump type | gear pump |
| Shaft material | EN225 |
| Built-in filter | yes |
| System type | single-pipe or two-pipe |
| Shaft standard | EN225 |
223.61 EUR
203.28EUR
in stock · 1
incl. 21% VAT · 168.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Danfoss BFP21 L3 oil pump (SKU 071N7170) is a gear pump designed for small and medium-sized household burners with fuel consumption up to 42 l/h. It operates within a pressure range of 7000–20000 mbar and handles fuel viscosity from 1.8 to 12.0 cst (mm2/s). The pump features a built-in filter with an area of 11 cm2 and a cross-section of 200 microns, and it supports both single-pipe and two-pipe systems. It is suitable for ambient temperatures from -20 to 70 °C and fuel temperatures from 0 to 70 °C, with a protection class of IP40. The shaft is made of EN225 material and rotates at speeds between 2400 and 3450 min.
Further details
| Coil protection degree | IP40 |
|---|---|
| Control Features | NC valve opens when powered, regulator maintains constant pressure |
| Factory settings | 10 ±1 bar |
| Shaft | EN225 |
Choosing and fitting
When selecting a replacement oil pump of this type, ensure the shaft standard (e.g., EN225) and rotation speed range match the burner's drive. Verify the pressure range and factory settings (typically 10 ±1 bar) align with the system requirements. Check the inlet pressure maximum (2000 mbar) and the maximum pressure in the suction/return line (2 bar) to avoid overpressure. Confirm the pump's fuel consumption capacity (up to 42 l/h) is sufficient for the burner's nozzle output. Also, match the system type (single-pipe or two-pipe) and ensure the mounting dimensions and shaft torque (0.1 Nm) are compatible.
Signs of failure
Common failures in gear pumps of this kind include loss of pressure due to worn gears or a clogged filter, leading to burner ignition issues or unstable flame. If the pump fails to deliver fuel, check the built-in filter for debris and verify the shaft rotates freely. Overheating or excessive noise may indicate bearing wear or misalignment. In two-pipe systems, a faulty bypass can cause fuel to leak or pressure fluctuations. Always inspect for fuel leaks around seals and connections, as these can lead to air ingress and poor combustion.
All specifications
| Protection class (IP) | IP40 |
|---|---|
| Viscosity range (suction line) | 1.8-12.0 cst(mm2/s) |
| Filter area / cross-section | 11/200 cm2/microns |
| Setting range | 7000–20000 mbar |
| Max. pressure in suction/return line | 2 bar |
| Shaft rotation speed | 2400-3450 min |
| Max. starting torque | 0.1 nm |
| Ambient temperature | -20–70 °C |
| Storage temperature | -25–120 °C |
| Fuel temperature | 0–70 °C |
| Max. inlet pressure | 2000 mbar |
| Torque, Nm | 0.1 Nm |
| Application | small and medium-sized household burners |
| Fuel consumption | 42 l/h |
| Pump type | gear pump |
| Shaft material | EN225 |
| Built-in filter | yes |
| System type | single-pipe or two-pipe |
| Shaft standard | EN225 |
Part numbers
| SKU | 071N7170 |
|---|---|
| Additional article | 327.520.130 |
| Model | BFP21 L3 |