Kromschroder Differential pressure switch DG150UG-3Z 84447527
SKU 84447527
Model DG150UG-3Z
Brand Kromschroder
Photos
Key specifications
| Gwint połączenia | M16 x 1.5 |
|---|---|
| Materiał obudowy | glass fibre reinforced PBT plastic |
| Electrical connection | screw terminals |
| Safety class | 1 |
| Lower housing material | AlSi 12 |
| Silicone-free | yes |
| Low gas release | yes |
| Line entrance thread | M16 x 1.5 |
| Screw terminals | yes |
| Trigger level adjustment | handwheel |
| Monitoring pressure changes | yes |
| Gas sensor | yes |
| Switching contact | microswitch with switching contact |
| Typ konstrukcji | diaphragm pressure switch |
237,34 EUR
215,76EUR
in stock · 1
incl. 21% VAT · 178,31 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Opis
Przełącznik ciśnieniowy membranowy Kromschroder DG150UG-3Z jest przeznaczony do monitorowania zmian ciśnienia w gazach lub powietrzu, reagując na odchylenia od zadanego punktu nastawienia. Wyposażony jest w mikrowyłącznik z kontaktem przełączającym, który aktywuje się po osiągnięciu nastawionego ciśnienia, a poziom wyzwalania reguluje się za pomocą pokrętła ręcznego. Obudowa wykonana jest z tworzywa PBT wzmocnionego włóknami szklanymi o niskiej emisji gazu, a dolna część obudowy z AlSi 12. Posiada membranę NBR wolną od silikonu, zaciski śrubowe do połączenia elektrycznego oraz gwint połączeniowy M16 x 1.5. Przełącznik jest przeznaczony dla gazu ziemnego, gazu miejskiego, LPG (gazowy), spalin, biogazu (maks. 0,1% obj. H2S) i powietrza, z klasą bezpieczeństwa 1.
Dobór i montaż
When selecting a pressure switch of this type, ensure the connection thread and line entrance thread match the existing installation, typically M16 x 1.5. The electrical connection must be compatible with screw terminals, and the switch should be chosen based on the medium and pressure range to be monitored. Mounting forms may vary, so verify the physical dimensions and enclosure rating (e.g., IP54 or IP65) to suit the environment. Before ordering, compare the trigger level adjustment mechanism and ensure it can be set to the required setpoint.
Objawy awarii
Common failure modes for diaphragm pressure switches include diaphragm rupture or leakage, which can cause the switch to fail to activate or deactivate at the set pressure. This may result in the burner or boiler not responding to pressure changes, leading to unsafe operation or shutdown. Check for signs of corrosion or damage to the housing and verify the electrical continuity of the microswitch. Also, inspect the diaphragm for wear or perforation, and ensure the adjustment handwheel is functioning correctly.
Wszystkie parametry
| Gwint połączenia | M16 x 1.5 |
|---|---|
| Materiał obudowy | glass fibre reinforced PBT plastic |
| Electrical connection | screw terminals |
| Safety class | 1 |
| Lower housing material | AlSi 12 |
| Silicone-free | yes |
| Low gas release | yes |
| Line entrance thread | M16 x 1.5 |
| Screw terminals | yes |
| Trigger level adjustment | handwheel |
| Monitoring pressure changes | yes |
| Gas sensor | yes |
| Switching contact | microswitch with switching contact |
| Typ konstrukcji | diaphragm pressure switch |
Part numbers
| SKU | 84447527 |
|---|---|
| Additional article | 624.214.018 |
| Model | DG150UG-3Z |