Brahma Ignition transformer T20 15570001
SKU 15570001
Model T20
Brand Brahma
Photos
Key specifications
| Supply voltage | 220 V |
|---|---|
| Secondary voltage | 5 kV |
| Poles / outlets | 2 |
| Length | 101 mm |
| Width | 80 mm |
| Height | 139 mm |
| Body material | pressed metal coated with enamel |
| Construction type | column type transformers |
| Operating principle | step-up transformer |
| Electrical connection | screw ø2.5 mm |
| Dimensions | 10.1x8x13.9 cm |
| Housing type | pressed metal coated with enamel |
| Weight | 3200 g |
| Catalogue article numbers | 15570001, 246.820.111 |
| Function | ignition transformer |
| Ingress protection | IP00 |
| Ignition cable connector | screw ø2.5 mm |
| Standard power cable length | 700 mm |
| Design features | various connection and mounting systems |
| Manufacturer code | 15570001 |
| Device type | ignition transformer |
| Includes ignition cable | yes |
| Ignition current | 23 mA |
| Winding configuration | 2 primary windings and 2 secondary windings |
| Dust and moisture protection | IP00 |
| Connector options | screw ø2.5 mm |
| Number of outputs | 2 |
| Duration of ED(DU) operation | 66 % |
| High voltage outputs | 2 |
| Transformer type | column type transformers |
| Housing material | pressed metal coated with enamel |
| Power supply | 220V |
| Manufacturer part number | 15570001 |
| Short name | Brahma 15570001 T20 ignition transformer |
| Name (English) | Brahma 15570001 T20 ignition transformer |
| SKU (English) | 15570001, 246.820.111 |
| Working cycle duration | 66 % |
| Power cable length included | 700 mm |
| Terminal type | screw ø2.5 mm |
| Designation | T20 |
| Suitable for steam boilers | steam boilers, kitchen stoves |
| High number of restarts | large number of restarts |
| Current | 1.3 A |
| Protection | IP00 |
| Mounting systems variety | various connection and mounting systems |
| Number of poles | 2 |
| Suitable for light and heavy oils | light or heavy oil |
| Identification letter | T |
| Model number | 20 |
| Energy consumption | 285 VA |
| Weight (approx) | 3.2 kg |
| Protection class (IP) | IP00 |
| connection_type | screw ø2.5 mm |
| Current consumption | 1.3 A |
| Mounting and connecting systems | various connection and mounting systems |
| Secondary current | 23 mA |
| Duty cycle | 66 % |
| Net weight | 3.2 kg |
| Power consumption | 285 W |
| Frequency | 50 Hz |
| Country of origin | Italy |
323.43 EUR
294.03EUR
in stock · 1
incl. 21% VAT · 243.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma T20 ignition transformer (SKU 15570001) is a column-type step-up transformer designed for ignition in burners and boilers. It operates on a 220 V supply at 50 Hz, consuming 285 W (VA) with a current draw of 1.3 A. The transformer provides a secondary voltage of 5 kV and an ignition current of 23 mA across two high-voltage outputs, with a duty cycle of 66%. It features two primary and two secondary windings, a pressed metal enamel-coated housing, and IP00 protection. The unit includes an ignition cable with a length of 700 mm and screw connectors (Ø2.5 mm). Weighing 3.2 kg, its dimensions are 10.1 x 8 x 13.9 cm. Suitable for steam boilers and kitchen stoves, it is designed for burners firing light or heavy oil and supports a large number of restarts.
Further details
| Designation meaning | T indicates transformer, 20 indicates model |
|---|---|
| High Voltage Insulation | special separator with a high degree of insulation |
| High voltage insulation method | special separator with a high degree of insulation |
| Insulation | special separator with a high degree of insulation |
| Insulation Separator | special separator with a high degree of insulation |
| Mounting system notation | standard mounting system not indicated; different mounting system indicated by letters |
| Same dimensions different characteristics | same overall dimensions, but different electrical characteristics and mounting systems |
| Suitable For High Thermal Output Burners | suitable for high thermal power burners or pressure burners for light or heavy oil |
| Technology | high discharge power; high efficiency and ignition power |
| Winding Insulation | special separator with a high degree of insulation |
Choosing and fitting
When selecting an ignition transformer of this type, ensure the supply voltage, frequency, and power consumption match the burner's electrical system. Verify the secondary voltage and current requirements of the ignition electrode. The mounting system must be compatible with the burner's bracket; various connection and mounting systems exist, so compare the physical dimensions and mounting hole patterns. The transformer's duty cycle (66%) must be adequate for the burner's operational cycle. Check the ignition cable length and connector type (screw Ø2.5 mm) to ensure proper connection.
Signs of failure
Common failures include open or shorted windings, leading to no spark or weak spark. Insulation breakdown can cause arcing to the housing or ground, resulting in erratic ignition or tripping of circuit breakers. Overheating due to excessive duty cycle or poor ventilation may cause internal thermal damage. Check for visible cracks or burn marks on the housing, measure primary and secondary voltages with a multimeter, and inspect the ignition cable and connectors for wear or corrosion.
All specifications
| Supply voltage | 220 V |
|---|---|
| Secondary voltage | 5 kV |
| Poles / outlets | 2 |
| Length | 101 mm |
| Width | 80 mm |
| Height | 139 mm |
| Body material | pressed metal coated with enamel |
| Construction type | column type transformers |
| Operating principle | step-up transformer |
| Electrical connection | screw ø2.5 mm |
| Dimensions | 10.1x8x13.9 cm |
| Housing type | pressed metal coated with enamel |
| Weight | 3200 g |
| Catalogue article numbers | 15570001, 246.820.111 |
| Function | ignition transformer |
| Ingress protection | IP00 |
| Ignition cable connector | screw ø2.5 mm |
| Standard power cable length | 700 mm |
| Design features | various connection and mounting systems |
| Manufacturer code | 15570001 |
| Device type | ignition transformer |
| Includes ignition cable | yes |
| Ignition current | 23 mA |
| Winding configuration | 2 primary windings and 2 secondary windings |
| Dust and moisture protection | IP00 |
| Connector options | screw ø2.5 mm |
| Number of outputs | 2 |
| Duration of ED(DU) operation | 66 % |
| High voltage outputs | 2 |
| Transformer type | column type transformers |
| Housing material | pressed metal coated with enamel |
| Power supply | 220V |
| Manufacturer part number | 15570001 |
| Short name | Brahma 15570001 T20 ignition transformer |
| Name (English) | Brahma 15570001 T20 ignition transformer |
| SKU (English) | 15570001, 246.820.111 |
| Working cycle duration | 66 % |
| Power cable length included | 700 mm |
| Terminal type | screw ø2.5 mm |
| Designation | T20 |
| Suitable for steam boilers | steam boilers, kitchen stoves |
| High number of restarts | large number of restarts |
| Current | 1.3 A |
| Protection | IP00 |
| Mounting systems variety | various connection and mounting systems |
| Number of poles | 2 |
| Suitable for light and heavy oils | light or heavy oil |
| Identification letter | T |
| Model number | 20 |
| Energy consumption | 285 VA |
| Weight (approx) | 3.2 kg |
| Protection class (IP) | IP00 |
| connection_type | screw ø2.5 mm |
| Current consumption | 1.3 A |
| Mounting and connecting systems | various connection and mounting systems |
| Secondary current | 23 mA |
| Duty cycle | 66 % |
| Net weight | 3.2 kg |
| Power consumption | 285 W |
| Frequency | 50 Hz |
| Country of origin | Italy |
Part numbers
| SKU | 15570001 |
|---|---|
| Additional article | 246.820.111 |
| Model | T20 |